Shaoxing Libo Electric Co., Ltd

Zhejiang Libo Industrial Co.,Ltd. Leading trunk cable manufacturer in China. Expert for leaky feeder cable.

Manufacturer from China
Site Member
13 Years
Home / Products / Leaky Feeder Cable /

Bare Copper Wire Braiding Leaky Antenna Feeder Cable for Coal Mine Communication

Contact Now
Shaoxing Libo Electric Co., Ltd
City:shaoxing
Province/State:zhejiang
Country/Region:china
Contact Person:MsMaria
Contact Now

Bare Copper Wire Braiding Leaky Antenna Feeder Cable for Coal Mine Communication

Ask Latest Price
Video Channel
Place of Origin :China
Brand Name :Libo
Certification :CE, ISO9000, ISO14001,RoSH, MSHA
Model Number :SLYWV-75-10 leaky feeder cable
MOQ :0.1km
Price :Call or e-mail to get the latest price
Packaging Details :350m/500m/1000m or according to client’s request
Delivery Time :5 days
Payment Terms :T/T, L/C,DP
Supply Ability :1000 KM per month
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Flame Retardant Jacket Leaky Feeder Cable SLYWV 75 - 10 Coal Mine Communication

Quick Details:

  • MSHA Certificate
  • Solid Oxygen Free Copper Inner Conductor
  • Bare Copper Wire Braiding
  • Low Smoke Halogen Free Jacket or Fire Retardant Jacket
  • VHF Leaky Feeder Cable
  • 75 Ohm Leaky Feeder Cable

Description:

MSHA certified leaky feeder cable, Meet IEC1196 and EN50117.

The leaky feeder cable has a radiation pattern of 360 degrees around the cable and can be strapped directly to a centenary cable, water or air pipe. The standard length is 350m or 500m with a yellow outer jacket.

Applications:

  • Mines underground communication system
  • metro stations
  • tunnels
  • ships
  • In-building wireless systems.
  • perimeter detection

Specification:

NO. Items Technical Requirements
1 Inner conductor CU 2.31±0.03mm
2 Dielectric FPE 9.50±0.20mm
3 Outer conductor CU 16*0.60mm
4 Inner jacket PE 13.0±0.30mm
5 Outer jacket PVC 15.5±0.50mm
6 impedance 75±3Ω
7 Frequency 5-500 MHz
8 DC resistance inner conductor ≤4.1Ω/km
9 DC resistance outer conductor ≤3.9Ω/km
10 Capacitance Pf/m 51±2
11 Insulation resistance >10.4Ω/km
12 MIN. bend radius 150mm
13 Coupling loss(50%), dB 65±10
14 Operating temperature -40 to +70 centigrade

15

Attenuation@20℃

≤dB/100m

85 MHz ≤3.4dB
150 MHz ≤4.2dB
160 MHz ≤4.8dB
450 MHz ≤6.1dB

Competitive Advantage:

  • Libo cable was established in 1994, it covers over 340,000 square meters on our operating area.
  • Libo cable has a stable workforce and engineering team, our production and testing procedures are all strictly follow requirement of ISO9000, and ISO14000.
  • Libo cable is equipped with a Provincial-level Research and Development Center; we offer OEM and ODM services.
  • Over 10 years of experience on leaky feeder cable, big market share in oversea leaky feeder cable industry.

Inquiry Cart 0